Challenges with Spring R2DBC Migrations Using Flyway
Jun 19, 2024
For prototyping and testing, the H2 database is a quick and easy solution. To use Flyway with R2DBC (Reactive Relational Database Connections), the following considerations are critical.
- Using the “In Memory” H2 Database will create two instances, and hence the Flyway and R2DBC will not be able to find the schemas.
- Must use the file or other modes for the R2DBC and Flyway configurations to work.
Observations
Upon applying the in-memory database configuration
spring.r2dbc.url=r2dbc:h2:mem:///examples;DATABASE_TO_UPPER=FALSE;DB_CLOSE_DELAY=-1;DB_CLOSE_ON_EXIT=FALSE;MODE=PostgreSQL;
spring.flyway.enabled=true
spring.flyway.url=jdbc:h2:mem:///examples;DATABASE_TO_UPPER=FALSE;DB_CLOSE_DELAY=-1;DB_CLOSE_ON_EXIT=FALSE;MODE=PostgreSQL;
spring.flyway.baseline-on-migrate=true
Errors
Table "tablename" not found (this database is empty); SQL statement:
SELECT table.* FROM table [42104-224]
Corrections
Apply the file-based database configuration to fix the table selection challenge.
spring.r2dbc.url=r2dbc:h2:file:////tmp/h2db/examples;DATABASE_TO_UPPER=FALSE;DB_CLOSE_DELAY=-1;DB_CLOSE_ON_EXIT=FALSE;MODE=PostgreSQL;
spring.flyway.enabled=true
spring.flyway.url=jdbc:h2:file:////tmp/h2db/examples;DATABASE_TO_UPPER=FALSE;DB_CLOSE_DELAY=-1;DB_CLOSE_ON_EXIT=FALSE;MODE=PostgreSQL;